BB20-20260929-01 · BPC-157 / TB-500 blend 20 mg

BPC-157 / TB-500 blend 20 mg · Lot BB20-20260929-01 · Result: Passed (blend)

Independent lab result

Lab

Uzorak, Zagreb, Croatia (EU)

Method

HPLC-UV, quantified against an external reference standard

Tested

6 Oct 2026

Purity

98.74% (blend)

Net content per vial

19.80 mg (BPC-157 10.03 mg + TB-500 9.77 mg) (label 20 mg)

Field note 5 of 7

99% pure is not 99% potent.

What this means

Both peptides were identified. Labs don’t report a formal purity for blends; 98.74% is the combined peak area of both peptides from the raw data, as explained to us by Uzorak. The TB-500 in this blend is the TB-500 fragment, not full-length thymosin beta-4.

Raw data from the lab

Uzorak sends the raw instrument data with every report. This is the chromatogram for this batch: each peak is a compound passing the detector, and its area shows how much of the sample it makes up.

HPLC-UV chromatogram for batch BB20-20260929-01 showing a TB-500 fragment peak at 23.27 minutes and a BPC-157 peak at 30.49 minutes, with the area percent report below
HPLC-UV chromatogram and area percent report, run 6 Oct 2026 (Uzorak report R87-162). Tap to enlarge.
  • TB-500 fragment, peak at 23.27 min: 26.96% of the total area.
  • BPC-157, peak at 30.49 min: 71.78% of the total area.
  • Together: 98.74%. This is the blend purity. Labs avoid the word “purity” for blends, so the formal report gives identity and mass instead; the figure comes from this raw data, as Uzorak explained to us.
  • Full-length TB-500 (thymosin beta-4), expected at 32.9 min: 0%. This is how we know the TB-500 in this blend is the fragment.

Why the areas aren’t 50/50. The two peptides absorb UV light differently, so peak area doesn’t show how much of each is in the vial. The amounts were measured separately against reference standards: 10.03 mg of BPC-157 and 9.77 mg of TB-500, close to the 10 mg + 10 mg on the label.

Our in-house checks

Carried out on 29 Sep 2026 when the batch arrived.

Check

Result

Identity

Pass

Vial integrity

Pass

Vacuum seal

Pass

Reconstitution

Pass

Mixing

Pass

Documents

Every document issued for this lot, oldest first. A reissue adds a row with its change note; the earlier files stay.

Document

Revision

Issued

Change

Rev 1.4

1 Nov 2026

Reissued from the site's document tool on 1 November 2026: new layout with headline figures, QR code to the lot page and document history. Results unchanged.

Rev 1.5

1 Nov 2026

Rev 1.5 (1 November 2026): table layout corrected; Rev 1.4 let the long result note push the Status column off the page. Results unchanged.

Rev 1.6

10 Nov 2026

Added 10 Nov 2026: the certificate now names the molecules identified, BPC-157 and the TB-500 fragment (Ac-LKKTETQ). Results unchanged.

Rev 1.7

26 Nov 2026

Reissued 26 November 2026: the lot link and QR code now point to batchtestlabs.co.uk, our permanent address. Results unchanged.

Back to The Record